EN 1047-1数据保险柜和磁盘的防火等级和测试方法
 
EN 1047-1数据保险柜和磁盘的防火等级和测试方法 – 标准名称
 
EN 1047-1: Secure storage units - Classification and methods of test for resistance to fire - Part 1: Data cabinets and diskette inserts
EN 1047-1文件柜,防火等级和试验方法,第1部分:数据保险柜和磁盘
 
EN 1047-1数据保险柜和磁盘的防火等级和测试方法 – 标准概述
 
该标准规定了防火数据保险柜和磁盘的要求。两种测试方法来确定防火数据保险柜的能力保护温度和湿度敏感内容的影响:耐火性测试和火灾冲击和冲击试验,,根据受火时间分为两个严重程度级别(60120);使用数据柜存储空间内允许的最大温升和湿度值,指定三个保护等级(p.d.DIS)

Scope:This part of this European Standard specifies requirements for fire resisting data cabinets and diskette inserts.
 
Two methods of test are specified to determine the ability of fire resisting data cabinets to protect temperature and humidity sensitive contents from the effects of fire: a fire endurance test and a fire shock and impact test, Two levels of fire severity (S 60 and S 120) based upon time of fire exposure; and three protection classes (P. D and DIS) are specified using the maximum temperature increases and humidity values permitted within the storage space of the data cabinet
 
EN 1047-1数据保险柜和磁盘的防火等级和测试方法 – 参考标准
 
EN 1363-1耐火测试,第1部分:一般要求
EN 60584-1热电偶。第1部分:参考表
EN 61515:无机矿物绝缘热电偶电缆和热电偶标准
 
----------------------------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------