CE Marking
Thermal Insulation Material for Building -Testing and Certificate
Thermal Insulation Material for Building -Testing and Certification
& Ecosafene have rich experience to provide Testing and Certification of Thermal insulation material for building
The term thermal insulation can refer to materials used to reduce the rate of heat transfer, or the methods and processes used to reduce heat transfer.
Heat energy can be transferred by conduction, convection, radiation or when undergoing a phase change. For the purposes of this discussion only the first three mechanisms need to be considered.
The flow of heat can be delayed by addressing one or more of these mechanisms and is dependent on the physical properties of the material employed to do this.
In Developed Countries, the use of thermal insulation material for building material has reach 75%, it is a big market.
Ä CE marking is MUST if you want to put your product into European Market
CE Marking Project
|
Directive
|
Standard
|
Remark
|
CE marking to mineralwool
|
89/106/EEC
|
EN 13162:2001
|
Reaction to fire, Thermal conductive, FPC
|
CE marking to Glasswool
|
89/106/EEC
|
EN 13162:2001
|
Reaction to fire, Thermal conductive, FPC
|
CE marking Rockwool
|
89/106/EEC
|
EN 13162:2001
|
Reaction to fire, Thermal conductive, FPC
|
CE marking to EPS
|
89/106/EEC
|
EN 13163:2001
|
Reaction to fire, Thermal conductive, FPC
|
CE marking to XPS
|
89/106/EEC
|
EN 13164:2001
|
Reaction to fire, Thermal conductive, FPC
|
CE marking to PUR
|
89/106/EEC
|
EN 13165:2001
|
Reaction to fire, Thermal conductive, FPC
|
CE Marking to PF
|
89/106/EEC
|
EN 13166:2001
|
Reaction to fire, Thermal conductive, FPC
|
CE marking to CG
|
89/106/EEC
|
EN 13167:2001
|
Reaction to fire, Thermal conductive, FPC
|
CE marking to WW
|
89/106/EEC
|
EN 13168:2001
|
Reaction to fire, Thermal conductive, FPC
|
CE marking to EPB
|
89/106/EEC
|
EN 13169:2001
|
Reaction to fire, Thermal conductive, FPC
|
CE marking to ICBCE
|
89/106/EEC
|
EN 13170:2001
|
Reaction to fire, Thermal conductive, FPC
|
CE marking to WF
|
89/106/EEC
|
EN 13171:2001
|
Reaction to fire, Thermal conductive, FPC
|
CE marking to Vermiculite
|
89/106/EEC
|
EN 14317-1:2004
|
Reaction to fire, Thermal conductive, FPC
|
Ä CE marking to Thermal Insulation Material for Building – EN Standard
Standard
|
Description
|
EN 13162:2001
|
Thermal insulation products for buildings-Factory made mineral wool(MW)products-Specification
|
EN 13163:2001
|
Thermal insulation products for building-Factory made products of expanded polystyrene(EPS)-Specification
|
EN 13164:2001
|
Thermal insulation products for buildings-Factory made products of extruded polystyrene foam(XPS)-Specification
|
EN 13165:2001
|
Thermal insulation products for buildings-Factory made rigid polyurethane foam(PUR)-Specification
|
EN 13166:2001
|
Thermal insulation products for buildings-Factory made products of phenolic foam(PF)-Specification
|
EN 13167:2001
|
Thermal insulation products for building-Factory made cellular glass(CG)-Specification
|
EN 13168:2001
|
Thermal insulation products for buildings-Factory made wood wool(WW)-Specification
|
EN 131369:2001
|
Thermal insulation products for building-Factory made products of expanded perlite(EPB)-Specification
|
EN 13170:2001
|
Thermal insulation products for buildings-Factory made products of expanded cork(ICB)-Specification
|
EN 13171:2001
|
Thermal insulation products for buildings-Factory made wood fibre(WF)-Specification
|
EN 13172:2001
|
Thermal insulating products-Evaluation of conformity
|
----------------------------------------------------------------------------------------------------------------------
- Previous:None
- Next:Fire detection, Fire alarm and Fire fighting system
----------------------------------------------------------------------------------------------------------------------