DIN 5510-2: Fire test to railway components

Article

&
  Ecosafene Products Service Co.,Ltd have rich experience to provide DIN 5510-2 fire test to railway components
 
Ä  DIN 5510-2 Fire test to railway components Standard
DIN5510-2 : Preventive fire protection in railway vehicles; Part 2: Fire behaviour and fire side effects of materials and parts, classification, requirement and test methods.
 
Ä  DIN 5510-2 Fire test to railway components Introduction
DIN 5510-2 determinate the fire classification of railway vehicle material and structure by burning behaviour, smoke density, dropping behavieour and toxic
 
Ä  DIN 5510-2 Fire test to railway component - Products Scope
DIN 5510-2 is acceptable to all train, railway vehicle, metro defined in EBO, ESBO, BOStrab
 
Ä  DIN 5510-2 Fire test to railway component - Test Method
 
ü  Fire test to railway components – small parts (handle, AD panel)
- Test Method: DIN 53438 –Testing of combustible materials; response to ignition by a small flame
- Classification: S1
 
ü  Fire test to railway componentsstructureseal, flooring, wall
- Test Method: DIN 54837 - Testing of materials, small components and component sections for rail vehicles - Determination of burning behaviour using a gas burner
- Classification: S2-S5, ST1-ST2, SR1-SR2
 
Burning Class
S2
S3
S4
S5
Destroy
≤30cm
≤25cm
≤20cm
0cm
After flame
Extinguish after test
≤100s
≤10s
0s
 
 
Drop Class
ST1
ST2
 
Smoke Class
SR1
SR2
Dropping
Yes
No
Smoke
≤100%.min
≤50%.min
 
ü  Fire test to railway components - flooringincluding adhesive and glue
- Test Method: ISO 9239-1 Reaction to fire tests for floorings -- Part 1: Determination of the burning behaviour using a radiant heat source
- Classification: SF1-SF3
Classification
SF1
SF2
SF3
CHF
≥2.5kw/m2
≥2.5kw/m2
≥4.5kw/m2
Smoke
--
≤2500%min
≤750%min
 
ü  Fire test to railway components - Seat
    - Test MethodDIN 5510-2, DIN EN 1021-1 and DIN EN 1021-2
 
ü  Fire test to railway components – Electrical device
- Test MethodEN 60695
 
ü  Fire test to railway components – Cable & Wire
- DIN EN 60332-1-2 Tests on electric and optical fibre cables under fire conditions
- DIN EN 50266-2-4 Common Test Methods for Cables under Fire Conditions
- DIN EN 61034-2 Measurement of smoke density of cables burning under defined conditions
 
>> Smoke toxic test according new version DIN 5510-2:2009:05, DIN EN ISO 5659-2, Smoke toxic test (toxicity measured with FTIR): FED<1
  
Ä  DIN 5510-2 Fire test to railway component – Material under products scope
 
- Rubber Products (Seal and filter
- Melamine foam for thermal insulation
- Sound insulation blanket
- Textile for curtain, seat backing
- Plastic Products (light shade, shell of cell)
- Flooring (glue and adhesive
- Cable
- Sound insulation blanket
- Electrical Device
- Fire-resistance paint
- Fire-redartant adhesive
- Seat (Sponge)
 
Ä  DIN 5510-2 Fire test to railway component 2 – Reference Standard
ü DIN 4102-1: fire behaviour of building materials and elements – Part 1: classification of building materials - requirements and testing
ü DIN 4102-8: Fire behaviour of building materials and components - Part 8: Small scale test furnace
ü DIN 5510-1: Preventive fire protection in railway vehicles - Part 1: levels of protection. fire preventive measures
ü DIN 5510-4: Preventive fire protection in railway vehicles - Part 4: vehicle design; safety requirements
ü DIN 5510-5: Preventive fire protection in railway vehicles – Part 5: electrical equipment; safety requirements
ü DIN 5510-6: Preventive fire protection in railway vehicles – Part 6: auxiliary measures. emergency brake operating function; information systems. fire alarms. fire fighting equipment; safety requirements
ü DIN 53438-1 Testing of combustible materials; response to ignition by a small flame; general data
ü DIN 53438-2 Testing of combustible materials; response to ignition by a small flame; edge ignition
ü DIN 53438-3 Testing of combustible materials; response to ignition by a small flame; surface ignition
ü DIN 54341: Testing of seats in railways for public traffic; determination of burning behaviour with a paper pillow ignition source
ü DIN 54837: Testing of materials, small components and component sections for rail vehicles - Determination of burning behaviour using a gas burner
ü DIN EN 597-1 Furniture. Assessment of the ignitability of mattresses and upholstered bed bases. Ignition source: smouldering cigarette
ü DIN EN 597-2Furniture. Assessment of the ignitability of mattresses and upholstered bed bases. Ignition source: match flame equivalent
ü DIN 1021-1: Furniture - Assessment of the ignitability of upholstered furniture - Part 1: Ignition source smouldering cigarette
ü DIN 1021-2: Furniture - Assessment of the ignitability of upholstered furniture - Part 2: Ignition source match flame equivalent
ü DIN EN 13501-1: Fire classification of construction products and building elements. Classification using test data from reaction to fire tests
ü DINEN 13501-2: Fire classification of construction products and building elements. Classification using data from fire resistance tests, excluding ventilation services
ü DIN EN 14390 Fire test - Large-scale room reference test for surface products
ü E DIN EN 45545-2 Railway applications. Fire protection on railway vehicles. Part 2. Requirements for fire behaviour of materials and components
ü DIN EN 50264-1: Railway applications - Railway rolling stock cables having special fire performance; Standard wall - Part 1: General requirements
ü DIN EN 50266-2-4 Common Test Methods for Cables under Fire Conditions - Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables Part 2-4: procedures – Category C
ü DIN EN 50266-2-5 Common Test Methods for Cables under Fire Conditions - Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables Part 2-5: procedures – Category D
ü DIN EN 50305: Railway applications. Railway rolling stock cables having special fire performance. Test methods
ü DIN EN 50306-1: Railway applications - Railway rolling stock cables having special fire performances - Thin wall - Part 1: General requirements
ü DIN EN 60332-1-2: Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame
ü DIN EN 60332-2-2 Tests on electric and optical fibre cables under fire conditions Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable Procedure for diffusion flame;
ü DIN 60695-11-10: Fire hazard testing. Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
ü DIN EN 61034-1: Measurement of smoke density of cables burning under defined conditions Part 1: Test apparatus.
ü DIN EN ISO 4589-2: Plastics - Determination of burning behaviour by oxygen index -- Part 2: Ambient-temperature test
ü DIN EN ISO 5659-2: Smoke generation -- Part 2: Determination of optical density by a single-chamber test
ü DIN EN ISO 9239-1: Reaction to fire tests for floorings -- Part 1: Determination of the burning behaviour using a radiant heat source
 
----------------------------------------------------------------------------------------------------------------------
[ Add to Favorites ]  [ Print this page ]  [ Close the window ]  [ Back to top ]