ASTM E108 Standard Test Methods for Fire Tests of Roof Coverings
ASTM E108 Standard Title:
ASTM E108 Standard Test Methods for Fire Tests of Roof Coverings
Standard Scope:
1.1 This fire-test-response standard covers the measurement
of the relative fire characteristics of roof coverings exposed to
simulated fire sources originating outside the building. It is
applicable to roof coverings intended for installation on either
combustible or noncombustible roof decks when applied as
intended for use. The following test methods are included:
1.1.1 Intermittent flame exposure test.
1.1.2 Spread of flame test.
1.1.3 Burning brand test.
1.1.4 Flying brand test.
1.1.5 Rain test.
Three classes of fire test exposure are described:
1.2.1 Class A Tests are applicable to roof coverings that are expected to be effective against severe fire exposure, afford a high degree of fire protection to the roof deck, do not slip from position, and are not expected to present a flying brand hazard.
1.2.2 Class B Tests are applicable to roof coverings that are expected to be effective against moderate fire exposure, afford a moderate degree of fire protection to the roof deck, do not slip from position, and are not expected to present a flying brand hazard.
1.2.3 Class C Tests are applicable to roof coverings that are effective against light fire exposure, afford a light degree of fire protection to the roof deck, do not slip from position, and are not expected to present a flying brand hazard.
ASTM E108 other Standrad:
NFPA256 Tests of Roof Coverings
ASTM D226 Specification for Asphalt-Saturated Organic Felt Used in Roofing and Waterproofing
ASTM D227 Specification for Coal-Tar-Saturated Organic Felt Used in Roofing and Waterproofing
ASTM ED312 Specification for Asphalt Used in Roofing
ASTM D2626 Specification for Asphalt-Saturated and Coated Organic Felt Base Sheet Used in Roofing