NF P92-503: Fire Test to Building Material (M Rating) - French Standard
& Ecosafene Products Service Co.,Ltd have rich experience to provide French Standard NF P92-503 fire test to Building Material
Ä NF P 92-503 Fire test to Building materials - Standard Title
NF P92-503: Safety against fire: Building materials – Reaction to fire tests. Electrical burner test used for flexible materials
Ä NF P 92-503 Fire test to Building materials - Standard Brief
NF P 92-503 Contain fire tests method of construction and decoration materials
Ä NF P 92-503 Fire test to Building materials - Products Scope
ü Flexible Material
ü Flexible filter material
ü Etc
Ä NF P 92-503 Fire test to Building materials - Test Method
NF P 92-503 M rating test Classify the fire test to M1, M2, M3, M4,M0 is the highest class
Observe the following Result in the test and classify the rating
ü Burning Time
ü Burning Time
ü Dropping
ü Destroyed length
Ä NF P 92-503 Fire test to Building materials – Reference Standard
ü NF C 42-321:1987 Appareils de mesurage électriques – Couples thermoélectriques – Tables de reference
ü NF C 42-323:1985 Appareils de mesurage électriques – Identification des couples thermoélectriques.
ü X 15-001:1991 Enceintes et conditions d’essais–Atmosphères normales de conditionnement ou d’essai
ü X 65-020:1991: Glossaire de termes relatifs au feu et de leurs définitions
Ä NF P 92-503 Fire test to building material – Similar Standard
Fire Test to Building Material according to French Standard – M Rating (M0,M1,M2,M3,M4)
ü NF P 92-510: Determination of upper calorific potential
ü NF P 92-501: Safety against fire: Building materials – Reaction to fire tests. used for rigid material or flexible materials thicker than 5mm
ü NF P 92-503: Safety against fire - Building materials -Reaction to fire tests - Electrical burner test used for flexible materials
ü NF P 92-504: Safety against fire - Building materials - Reaction to fire tests - Flame persistence test and speed of the spread of flame.
ü NF P 92-505: Safety against fire - Building materials - Reaction to fire tests - Test used for thermal melting materials - Dripping test.
ü NF P 92-506: Safety against fire - Building Material - Flooring
ü NF P92-507: Fire safety - Building - Interior fitting materials - Classification according to their reaction to fire
----------------------------------------------------------------------------------------------------------------------