DIN EN 50305 / EN 50305 Toxicity test for cable

Article

 
 
DIN EN 50305 / EN 50305 Toxicity test for cable
 
 
DIN EN 50305 Toxicity test - Standard
 
DIN EN 50305 Railway applications-Railway rolling cables having special fire performance-Test methods, Clause 9.2 Toxicity
 
DIN EN 50305 Toxicity test – Test conditions
 
Prior to testing, all test pieces was conditioned at least 48 h in an atmosphere having a temperature of 23±2°C and a relative humidity of 50±5%.
 
DIN EN 50305 Toxicity test - Requirement
 
According to DIN 5510-2 test standard,
Requirements :  I.T.C Values≤ 3Refer to DIN EN 50264-1:2008
 
DIN EN 50305 Toxicity test - Critical Concentration
 
CCZ Values for varions gased
Gas
CCZ
Carbon Dioxide(CO2)
90 000
Carbon Monoxide(CO)
1750
Hydrogen Cyanide(HCN)
55
Nitrogen Oxides(NO2)
90
Sulphur Dioxide (SO2)
260
 
DIN EN 50305 Toxicity test – Reference Standard
 
-  DIN5510-2 : Preventive fire protection in railway vehicles; Part 2: Fire behaviour and fire side effects of materials and parts, classification, requirement and test methods.
-  EN45545-2: Fire protection of railway vehicles - Part 2: Requirement for fire behaviours of materials and components
-  EN60332-3-24: 2010-08 Test on Electric and Optical Fibre Cables under Fire Conditions Part 3-24: Test For vertical flame spread of vertically---Mounted bunched wires or cables Category C (IEC 60332-3-24:2000 + A1:2008)
-  DIN EN 50266-2-4:: Common test methods for cable under fire condition—Test for vertical flame spread of vertically-mounted bunched wires or cables –Part 2-5: Procedures –Category C
-  DIN EN 50266-2-4:: Common test methods for cable under fire condition—Test for vertical flame spread of vertically-mounted bunched wires or cables –Part 2-5: Procedures –Category C
-  DIN EN 50305: Railway applications. Railway rolling stock cables having special fire performance. Test methods
-  DIN EN 60332-1-2: Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame
-  DIN EN 61034-1: Measurement of smoke density of cables burning under defined conditions Part 1: Test apparatus
 
 
 
----------------------------------------------------------------------------------------------------------------------
[ Add to Favorites ]  [ Print this page ]  [ Close the window ]  [ Back to top ]
Copyright EcoSafene  闽ICP备09009213号-1