BS 7846: Electric cables – 600/ 1000V armoured fire-resistant cables

Article
 
BS 7846: Electric cables – 600/ 1000V armoured fire-resistant cables
 
BS 7846: Electric cables – 600/ 1000V armoured fire-resistant cables - Test Standard
 
BS 7846:Electric cables – 600/ 1000V armoured fire-resistant cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire 
 
BS 7846: Electric cables – 600/ 1000V armoured fire-resistant cables -Scope:
 
This British Standard specifies the requirements for construction and performance,and describes methods of test, for armoured fire-resistant cables with thermosetting insulation and of rated voltage 600/1000V and low emission of smoke and corrosive gases when affected by fire.
 
The circuit integrity performance under fire conditions is assessed on the basis of various tests which either separately measure resistance to fire,resistance to fire with water,and resistance to fire with water,and resistance to fire with mechanical shock(Categories F1 and F2),or in combination measure resistance to fire with mechanical shock and water.(Category F3)
 
BS 7846: Electric cables – 600/ 1000V armoured fire-resistant cables -Sample required
20m
 
BS 7846: Electric cables – 600/ 1000V armoured fire-resistant cables - Relative Standard
 
- BS 5099 Electric cables- Voltage levels for spark testing
- BS 63871994 Specification for Performance Requirements for Cables Required to Maintain Circuit Integrity Under Fire Conditions
- BS 84912008 Method for assessment of fire integrity of large diameter power cables for use as components for smoke and heat control systems and certain other active fire safety systems
- BS 10244—22009 Steel wire and wire products - Non-ferrous metallic coatings on steel wire - Part 2: Zinc or zinc alloy coatings
- BS EN 50363-5 Insulating sheathing and covering materials for low voltage energy cables
- BS EN 60228 Leiter fuer Kabel und isolierte Leitungen Conductors of insulated cables Ames des cables isoles CORR 17085:May 31,2007
- BS EN 60332-1-2:2004 Tests on electric and optical fibre cables under fire conditions—Part 1-2: Test for vertical flame propagation for a single insulated wire or cable
- BS EN 62230 Electric cables- spark-test method
 
----------------------------------------------------------------------------------------------------------------------
[ Add to Favorites ]  [ Print this page ]  [ Close the window ]  [ Back to top ]